Sources of systematic error in the sampling procedure by Winkler method were examined. In the laboratory experiment, the dissolution of atmospheric oxygen into oxygenfree sea water during sampling amounts to 0.022 ml/l, and the effect of dissolved oxygen in sea water remaining in oxygen bottle is 0.019 ml/l. The effect of reagents added amounts to 0.017 ml/l. In the sampling procedures aboard, the effect of dissolution became bigger, and the table is presented for the correction to the reported value of dissolved oxygen measured by the “Manual of Oceanographic Observation”. The corrected value of dissolved oxygen in the routine analysis may not be correct within 0.02 m