首页> 外文期刊>IEEE Transactions on Magnetics >Two-Dimensional FEA-Based Iron Loss Calculation Method for Linear Oscillating Actuator Considering the Circumferential Segmented Structure
【24h】

Two-Dimensional FEA-Based Iron Loss Calculation Method for Linear Oscillating Actuator Considering the Circumferential Segmented Structure

机译:

获取原文
获取原文并翻译 | 示例
           

摘要

Linear compressors have a simpler mechanical structure and higher efficiency than rotary compressors because they have lower frictional loss. Therefore, the linear oscillating actuator (LOA) is an attractive option for compressors owing to its high power density and efficiency. However, the complex structure of LOA such as segmented outer stator and mover leads to conduct 3-D finite element analysis (FEA) for calculating accurate iron loss, but it requires high computation cost. Thus, we propose a method to calculate iron loss only using 2-D axisymmetric FEA considering the permeance in the stator core. To compensate for the alterations in the magnetic flux density resulting from the structure of the mover and outer stator of the LOA, two equivalent coefficients are applied in permanent magnets in the mover to correct the induced voltage and the outer stator to correct the magnetic flux density. Through the utilization of these two equalization methods, iron loss can be accurately calculated using only 2-D axisymmetric FEA. The proposed method can be used to accurately determine the efficiency of the LOA without 3-D FEA, thus, making the LOA design process more efficient.

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号