首页> 美国政府科技报告 >Study of Two Control Methods for Full Bridge Converters: Soft Switch Bypass andCurrent Mode Control
【24h】

Study of Two Control Methods for Full Bridge Converters: Soft Switch Bypass andCurrent Mode Control

机译:全桥变换器两种控制方式的研究:软开关旁路和电流模式控制

获取原文

摘要

In a broad sense, there are now 3 basic categories for high power (above severalKW) DC/DC converters: (1) Forced commutation (FC) (2) Resonant (R) (3) Soft switch (SS). Some topologies that are combinations of the above also have been proposed, such as certain pulse width modulation (PWM)-resonant arrangements. The first part of this project was a proposed improvement of the third category, the soft switch. The basic idea of this new converter was to use two additional switches that would bypass the loading during part of the operating cycle if the current decreased below a certain level. The motivation for this was to retain the soft switching characteristic at light loads--a common problem with soft switch converters. Although the bypass circuit proved functional, certain problems were uncovered which raise doubts about its ultimate feasibility. Because of these problems, the research emphasis was shifted from the bypass to an improve current mode control (CMC) converter that promised better results. (rh)