首页> 美国政府科技报告 >Design and Testing of a Pulsed Current Transformer
【24h】

Design and Testing of a Pulsed Current Transformer

机译:脉冲电流互感器的设计与测试

获取原文

摘要

A pulsed current transformer was built and tested. Data substantiating the theoretical model was obtained. The four turn, coaxial geometry transformer had a mean radius of 12 inches. It used copper tubing for the secondary and number 6 gage wire for the primary. Under short circuit conditions, the time-to-peak current was 70 microseconds and a time averaged turns ratio of 3.75 was produced by the transformer. The theoretical model yielded an input inductance of 1.93 microhenries while the high frequency measurement yielded 1.66 microhenries. By increasing the secondary wall thickness, this device will be useful in electromagnetically stressing barrel test sections at the megampere level.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号