This letter presents the results of the bioventing system monitoring performed by Parsons Engineering Science, Inc. (Parsons ES) in December 1996 at Sites ST 12-A and ST 12-B, located at the Waikakalaua Fuel Storage Annex (FSA) administered by Hickam Air Force Base (AFB), Hawaii. Soil gas samples were collected and in situ respiration testing was performed by Parsons ES between 10 and 23 December 1996 to assess the extent of remediation completed during approximately 3.5 years of air injection bioventing at Site ST 12-A and 1 year of air injection bioventing at Site ST 12- B. The purpose of this letter is to summarize remediation activities to date, present the results of the December 1996 system monitoring event and compare them with the results of previous monitoring events, and to outline future remediation activities planned for Sites ST12-A, ST12-B, and ST1O, which is located at Valve Pit 17 on the Hickam POL pipeline near Kipapa FSA.