首页> 美国政府科技报告 >Corrosion Monitoring in Hanford Nuclear Waste Storage Tanks, Design and Data From 241-AN-102 Multi-Probe Corrosion Monitoring System
【24h】

Corrosion Monitoring in Hanford Nuclear Waste Storage Tanks, Design and Data From 241-AN-102 Multi-Probe Corrosion Monitoring System

机译:汉福德核废料储罐的腐蚀监测,241-aN-102多探头腐蚀监测系统的设计和数据

获取原文

摘要

In 2008, a new Multi-Probe Corrosion Monitoring System (MPCMS) was installed in double-shell tank 241-AN-102 on the U.S. Department of Energy's Hanford Site in Washington State. Developmental design work included laboratory testing in simulated tank 241-AN-102 waste to evaluate metal performance for installation on the MPCMS as secondary metal reference electrodes. The MPCMS design includes coupon arrays as well as a wired probe which facilitates measurement of tank potential as well as corrosion rate using electrical resistance (ER) sensors. This paper presents the MPCMS design, field data obtained following installation of the MPCMS in tank 241-AN-102, and a comparison between laboratory potential data obtained using simulated waste and tank potential data obtained following field installation.