DOE asked ORNL to devise a procedure for selecting an optimum combination of building shell and heating system retrofits for single-family dwellings. To determine the best retrofits for each house that would maximize program savings, ORNL staff members developed an approach that used information from a preretrofit energy audit of candidate houses. Audit results are used to estimate annual energy savings for various retrofits for each house. Life-cycle benefits (B) are calculated, as are the estimated installation costs (C) for given retrofits in given houses. The benefits-to-cost ratios (B/Cs) are then ranked for all possible retrofits to all candidate houses, and the top-ranking B/C retrofits are selected for installation. This process maximizes program savings, and it is adaptable to varied housing types in different climates. The Audit-Directed Retrofit Program (ADRP) was field tested in a low-income housing retrofit program in Wisconsin during the winter of 1985-86. Results of the field test are reported in a companion document. This report describes the ADRP for the benefit of potential users. (ERA citation 12:049774)