This report presents results of a project conducted by the S.M. Stoller Corpora¬tion for EPRI. The purpose of the project was to analyze the operational experi¬ence of nuclear units within the United States during the calendar years 1985 through 1986 using the Operating Plant Evaluation Code (OPEC-2) System and other available sources of operational data.nThe report updates and supplements previous EPRI reports NP-1191, NP-2092, NP-3480, and NP-4368. The overall performances of U.S. nuclear units and the availability and capacity factor losses for the constituent systems and components are presented. The problem areas which have impacted most significantly on nuclear unit performance during 1985 to 1986 are discussed in detail. Forced outage rates and scram rates are also investigated. The 92 domestic nuclear units which were considered in this report include all units which are rated 400 MW(e) or greater. Three Mile Island 2 was excluded from all analyses of this report. The performances of BWRs and PWRs in the United States during 1985 through 1986 were compared with similar units operating in foreign countries.