首页> 美国政府科技报告 >Removable of Trace Radionuclides and Chemical Contaminants from Waste Evaporator Condensates by Electrodialysis
【24h】

Removable of Trace Radionuclides and Chemical Contaminants from Waste Evaporator Condensates by Electrodialysis

机译:电渗析法从废蒸发器凝结水中去除痕量放射性核素和化学污染物

获取原文

摘要

The feasibility of using electrodialysis, a membrane separation process, to remove radioactive and chemical contaminants from Process Equipment Waste (PEW) evaporator condensates was evaluated with a one-hundredth scale vendor-built pilot plant. Decontamination efficiencies (DE) for nine radionuclides and six chemical contaminants were determined. Excluding plutonium, which behaved erratically, the average radionuclide DE was 96%. Nitric acid removal averaged 98%, while the average DE for mercury was 83%. To a large extent, radionuclide removal was due to sorption on the membranes. Seventy-two percent of the input radioactivity for eleven runs became sorbed on the membranes. (ERA citation 12:006564)