Changes in the mechanical properties of cold-formed A 500 structural steel tubing occurred at and above room temperature due to strain aging. Reduction in longitudinal ductility (% elongation) due to strain aging was, however, not found to be significant in this study. Tubing fabricated from aluminium-killed steel appeared to respond less to strain aging at room temperature than nonkilled steel. Aluminum-killed material did not, however, eliminate strain aging. This study suggests that lateral strains as produced in square and rectangular shapes cold-formed from round tubing do not have the same effect on longitudinal ductility as does longitudinal straining. Comparison of individual tensile tests to represent a given state of strain aging produces excessive random data scatter to be meaningful. A minimum of 5 test samples to characterize each temper state is recommended. (ERA citation 11:051291)