首页> 美国政府科技报告 >TMI-2 Pressure Transmitter Examination Program Year-End Report: Examination and Evaluation of Pressure Transmitters CF-1-PT3 and CF-2-LT3
【24h】

TMI-2 Pressure Transmitter Examination Program Year-End Report: Examination and Evaluation of Pressure Transmitters CF-1-PT3 and CF-2-LT3

机译:TmI-2压力变送器检测程序年终报告:压力变送器CF-1-pT3和CF-2-LT3的检查和评估

获取原文

摘要

This report discusses the pressure transmitter portion of the DOE-sponsored Data Acquisition program at TMI-2. In particular, two transmitters were removed from the TMI-2 Reactor Building and evaluated in the laboratory in order to establish their operational characteristics. One unit, a Foxboro gauge pressure unit, survived the accident and subsequent handling, shipping, and storage with no apparent problems. The other unit, a Bailey differential pressure unit, apparently failed in operation at an unknown time, probably from water in the unit, and subsequently corroded so badly as to make failure analysis extremely difficult. A compilation of information on pressure transmitters located in the Reactor Builidng is presented. (ERA citation 08:014935)