首页> 美国政府科技报告 >Supercritical Heat-Exchange Field Test: Field-Performance Data on Shell-and-Tube Heat Exchangers in Geothermal Service
【24h】

Supercritical Heat-Exchange Field Test: Field-Performance Data on Shell-and-Tube Heat Exchangers in Geothermal Service

机译:超临界热交换现场试验:地热服务中管壳式换热器的现场性能数据

获取原文

摘要

Presented are results from a binary-cycle test loop. Results cover loop operational problems, overall heat transfer coefficients, LMTD's, and duties for six primary heaters in counterflow having brine in the tubes and hydrocarbon in the shells, and for a condenser. Fluids tested were isobutane and mixtures of isobutane/isopentane; each heated at supercritical conditions and condensed at subcritical conditions. (ERA citation 08:004879)