首页> 美国政府科技报告 >Operation of the New Hermes II Marx
【24h】

Operation of the New Hermes II Marx

机译:新爱马仕二世的运作马克思

获取原文

摘要

Because of the unavailability of replacement capacitors of the type used since 1968, it became necessary by early 1980 to plan for a new replacement Marx generator in Hermes II. This replacement was accomplished during the period between October 1, 1980 and March 1, 1981. The new Marx consists of four modules in series, each of which is similar to a PBFA-II Marx, for a total of 128 capacitors. The erected capacitance is 10 nF, the inductance is 25 mu H, and the maximum capacitor charge voltage is 100 kV. The total run time from fire command until diode output is about 2 mu s. This 2 mu s includes approximately 300 ns trigger Marx run time, 900 ns Marx erection time, and 900 ns Blumlein charge time. Due to the faster Blumlein charge time, the new Bremsstrahlung radiation output from Hermes II has increased by 60% compared to that with the old Marx. A unique new shorting system has been added which can short each capacitor individually thereby ensuring a completely discharged Marx and a safer system to work on during repairs and maintenance. (ERA citation 81:026710)