A heat-exchanging fireplace was installed in a 2000 square foot home and the standard air distribution equipment was ducted directly to the forced-air heating system of the home. The standard air distribution equipment for the fireplace included two squirrel-cage blowers which were connected to a thermostat, allowing a choice of temperature ranges; and a snap disc thermostat was used to disconnect the blowers in order to avoid blowing cold air after the fire died out. Arranged in this manner, one is able to set the regular home thermostat a few degrees lower than the fireplace thermostat, and this will allow the regular heating system to turn on after the fire has gone out in the fireplace. Energy consumption in both the fireplace and the conventional heating system was monitored throughout a heating season and then compared with past heating seasons when only a conventional heating system was used. (ERA citation 09:000695)