首页> 美国政府科技报告 >EFFECTS OF TORUS WALL FLEXIBILITY ON FORCES IN THE MARK I BWR PRESSURE SUPPRESSION SYSTEM - EXTENDED ANALYSES UNDER SRV T-QUENCHER LOADING
【24h】

EFFECTS OF TORUS WALL FLEXIBILITY ON FORCES IN THE MARK I BWR PRESSURE SUPPRESSION SYSTEM - EXTENDED ANALYSES UNDER SRV T-QUENCHER LOADING

机译:标记I BWR压力抑制系统中扭矩壁柔性对力的影响 - sRV T-淬火加载下的扩展分析

获取原文

摘要

This report describes a series of extended analyses requested by the U. S. Nuclear Regulatory Commission to provide qualified understanding of possible fluid/structure interaction (FSI) effects for SRV teequencher test results. Three input pulses with total impulses varying by up to a factor of five are applied to two-dimensional finite-element models of the Mark I torus with shell diameter-to-thickness ratios of 0, 300, and 600. The results of these analyses support earlier conclusions that increased wall flexibility enhances attenuation of hydrodynamic loads and furthermore indicate that the magnitude of the attenuation is only weakly affected by the total impulse of the bubble pressure time-history.