It is concluded that: l. The HYGAS experiment testing capacitive measurement of mass flow has shown the method to be feasible. 2. The capacitive method provides an absolute measure of the stream velocity, neglecting the question of correction for flow profiles. That is, the method is absolute but may not be precise. 3. The calibrated density value of capacitance versus char concentration in percent by weight is approximately linear. It appears to be a useful measure of solids concentration in the slurry. 4. Auxiliary measurements of density and temperature are needed to improve the interpretation of the signals obtained from the capacitive measurement. 5. Signal-to-noise ratios obtained were sufficiently good to encourage the development of an inexpensive on-line electronic readout system. 6. Further work is needed on the design of the density electrodes to improve the zero stability. Variations in the air filled value are attributed to unwanted contributions from dielectrics outside the desired measurement region. (ERA citation 04:021168)