首页> 美国政府科技报告 >Boise Paper: Pumping System Optimization Saves Energy and Improves Production
【24h】

Boise Paper: Pumping System Optimization Saves Energy and Improves Production

机译:博伊西纸业:泵送系统优化节省能源并改善生产

获取原文

摘要

To improve the efficiency of the bleach plant's process pumping system, engineers at the Boise Paper mill in Wallula, Washington, implemented a system improvement project in 2005. The plant's process pumping system was evaluated during a course taught by Don Casada, a U.S. Department of Energy (DOE) Qualified Pumping System Assessment Tool (PSAT) Specialist. This assessment was supported by the Northwest Energy Efficiency Alliance (NEEA), and results were later corroborated by Tim Dugan of Compression Engineering Corporation in an evaluation funded by the mill's electric utility, Pacific Power. This project greatly improved the plant's process pumping system efficiency. Based on measurements of the system's use, the project yields approximate annual electricity savings of 498,000 kWh, electricity cost savings of $15,157, and maintenance cost savings of $2,500. An incentive from Pacific Power brought total project costs to $74,000, resulting in a 4.2-year simple payback.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有