The inventory of dust in next-step magnetic fusion devices will be regulated for safety reasons, however diagnostics to measure in-vessel dust are still in their infancy. Advances in dust particle detection on remote surfaces are reported. Two grids of interlocking circuit traces with spacing in the range 125 mu m to 25 mu m are biased to 30 V. Impinging dust creates a short circuit and the result current pulse is recorded. The detector response was measured with particles scraped from a carbon fiber composite tile and sorted by size category. The finest 25 mu m grid showed a sensitivity more than an order of magnitude higher than the 125 mu m grid. The response to the finest particle categories (5 *30 mu m) was two orders of magnitude higher than the largest (125 *250 mu m) category. Longer duration current pulses were observed from the coarser particles. The results indicate a detection threshold for fine particles below 1 mu g/cm.(up arrow) 2.