首页> 美国政府科技报告 >Measurement of Injector Face Temperature Using Optical Diagnostic Techniques
【24h】

Measurement of Injector Face Temperature Using Optical Diagnostic Techniques

机译:利用光学诊断技术测量喷射器面温

获取原文

摘要

A CCD camera was previously set up to record infrared images of the injector face of a small rocket combustor. Good semi-quantitative results were obtained but it was found that non-linearities in the camera system made accurate determinations of temperature difficult. A Pulnix CCD camera was purchased and calibrated. The system was calibrated for temperatures between 500 and 850 C. The best filter to use was found to be a BG850 glass filter. The actual calibrations are presented in the report. The system was to be used on a hydrogen oxygen system but the tests did not take place as scheduled. Attempts were made with a methane oxygen system but the carbon in the system interfered with the viewing of the injector face.