首页> 美国政府科技报告 >Measured performance of the heat exchanger in the NASA icing research tunnel under severe icing and dry-air conditions
【24h】

Measured performance of the heat exchanger in the NASA icing research tunnel under severe icing and dry-air conditions

机译:在严酷的结冰和干燥空气条件下,Nasa结冰研究隧道中热交换器的性能测量

获取原文

摘要

Measurements were made of the pressure drop and thermal perfomance of the unique refrigeration heat exchanger in the NASA Lewis Icing Research Tunnel (IRT) under severe icing and frosting conditions and also with dry air. This data will be useful to those planning to use or extend the capability of the IRT and other icing facilities (e.g., the Altitude Wind Tunnel-AWT). The IRT heat exchanger and refrigeration system is able to cool air passing through the test section down to at least a total temperature of -30 C (well below icing requirements), and usually up to -2 C. The system maintains a uniform temperature across the test section at all airspeeds, which is more difficult and time consuming at low airspeeds, at high temperatures, and on hot, humid days when the cooling towers are less efficient. The very small surfaces of the heat exchanger prevent any icing cloud droplets from passing through it and going through the tests section again. The IRT heat exchanger was originally designed not to be adversely affected by severe icing. During a worst-case icing test the heat exchanger iced up enough so that the temperature uniformaity was no worse than about /- 1 deg C. The conclusion is that the heat exchanger design performs well.