首页> 美国政府科技报告 >Novel Method for Determination of Critical Humidity Levels of the Binding Surface between Concrete and Sealant. Part 1
【24h】

Novel Method for Determination of Critical Humidity Levels of the Binding Surface between Concrete and Sealant. Part 1

机译:混凝土与密封胶结合面临界湿度测定的新方法。第1部分

获取原文

摘要

A method has been developed that is intended to be used for investigating the humidity load on the interface between a primer or a concrete surface and the sealant. This is done by means of a new technique comprising a construction called 'joint simulator,' which is described in detail in the report. The evaluation is done according to a slightly modified peel test (ASTM 6794). In conclusion, the humidity level plays an important role when jointing concrete surfaces.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号