首页> 美国政府科技报告 >Fatality Assessment and Control Evaluation (FACE) Report: Two Volunteer Fire Fighters Die After an Explosion While Attempting to Extinguish a Fire in a Coal Storage Silo - South Dakota.
【24h】

Fatality Assessment and Control Evaluation (FACE) Report: Two Volunteer Fire Fighters Die After an Explosion While Attempting to Extinguish a Fire in a Coal Storage Silo - South Dakota.

机译:死亡率评估和控制评估(FaCE)报告:两名志愿消防员在爆炸时死亡,同时试图熄灭煤炭仓库 - 南达科他州的火灾。

获取原文

摘要

On September 15, 2011 a 20-year-old male, and a 22-year-old male, both volunteer fire fighters, were killed while attempting to extinguish a fire in a coal storage silo. After removing approximately 80 of the 100 tons of coal inside the silo, the two victims attempted to extinguish the fire by applying water through an access hatch on top of the 50 foot silo. An explosion occurred destroying the silo and killing the two victims. A third fire fighter working inside the structure at the base of the silo was seriously injured. Contributing Factors: 1. Silo design; 2. Unique explosive characteristics of coal (Bituminous, Sub-Bituminous including Powder River Basin Coal); 3. Fire fighting tactics for silo fires. Key Recommendations: 1. Fire departments should review, revise and enforce standard operating guidelines (SOGs) for structural fire fighting that address silos containing combustible particles; 2. Fire departments should train officers and fire fighters on the hazards associated with different types of silos and the appropriate fire fighting tactics including any special hazards posed by the silo contents; 3. Fire departments should ensure that pre-emergency planning is completed for all types of silos located within fire department jurisdictions. Additionally, governing municipalities, manufacturers, and designers of coal storage silos should: 1. consider requiring that placards with hazard warnings and appropriate fire fighting guidelines be placed on silos; 2. ensure that silos are constructed so that the contents flow without becoming trapped (stagnant) and to limit the introduction of air into the silo.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号