首页> 美国政府科技报告 >Evaluation and Validation of Equivalent Circuit Photovoltaic Solar Cell Performance Models
【24h】

Evaluation and Validation of Equivalent Circuit Photovoltaic Solar Cell Performance Models

机译:等效电路光伏太阳能电池性能模型的评估与验证

获取原文

摘要

The five-parameter model is a performance model for photovoltaic solar cells that predicts the voltage and current output by representing the cells as an equivalent electrical circuit with radiation and temperature-dependent components. An important feature of the five-parameter model is that its parameters can be determined using data commonly provided by module manufacturers on their published datasheets. This paper documents the predictive capability of the five-parameter model and proposes modifications to improve its performance using approximately 30 days of field-measured meteorological and module data from a wide range of cell technologies, including monocrystalline, polycrystalline, amorphous silicon, and copper indium diselenide (CIS). The standard five-parameter model is capable of predicting the performance of monocrystalline and polycrystalline silicon modules within approximately 6% RMS but is slightly less accurate for a thin-film CIS and an amorphous silicon array. Errors for the amorphous technology are reduced to approximately 5% RMS by using input data obtained after the module underwent an initial degradation in output due to aging.