NIOSH evaluated eight dry cleaning shops to determine the extent of exposure and the technological feasibility of controlling worker exposure to perchloroethylene (Perc). In this study, dry cleaning plants were selected and data taken to characterize worker exposure levels and control technology for 'fourth generation' closed-loop, dry-to-dry machines (with an integrated, in-line refrigerated condenser and a carbon absorber to recover Perc vapors during the dry cycle), and 'fifth generation' machines, having the same features as fourth generation machines plus an internal monitor/interlock system to prevent door opening at Perc concentrations above a set level. Full shift time-weighted average (TWA) and short duration. Ceiling and 15 minute Short Term Exposure Level (STEL) Perc exposures were measured on several workers in each shop. Information was collected at each dry cleaning plant to correlate Perc measurements with controls and equipment. Results of measurements at Ten Ten Cleaners indicate a range of 2,000 ppm and 0.2 to 60 ppm, with half the measurements of ceiling and STEL levels below 168 ppm and 4.2 ppm, respectively.