首页> 美国政府科技报告 >Fatigue of Stud Shear Connectors in the Negative Region of Steel Girder Bridges:A Synopsis of Experimental Results and Design Recommendations. Final Report
【24h】

Fatigue of Stud Shear Connectors in the Negative Region of Steel Girder Bridges:A Synopsis of Experimental Results and Design Recommendations. Final Report

机译:钢梁桥负区螺柱剪连接件的疲劳:实验结果与设计建议简介。总结报告

获取原文

摘要

In a simply supported bridge girder the concrete is in compression over the fulllength of the bridge, whereas in a continuous multispan bridge some regions of the bridge are subjected to negative bending moment, in which case the concrete goes into tension. With respect to fatigue behavior of stud shear connectors, one key difference between placing studs in the positive and negative moment regions is the stress state of the base metal of the beam flange. The fact that the beam flange is in tension at the base of the studs in the negative moment region raises questions about whether this affects their fatigue endurance. This report summarizes the research behind the fatige design provisions for shear connectors in the negative moment region in the American Association of State Highway Transportation officials (AASHTO) Load and Resistance Factor Design (LRFD) Specification.