摘要

The objectives were to identify whether ceiling installed radiant heating panels can provide thermal comfort to the occupants in a patient room, and to determine a method for optimal thermal environment to both patient and medical staff simultaneously. The experiments were performed in a climate chamber resembling a single-bed patient room under convective air conditioning alone or combined with the ceiling installed radiant heating panels. Two thermal manikins simulated a patient lying in the bed and a doctor standing next to the patient. Conventional cotton blanket, electric blanket, electric mattress were used to provide local heating for the patient. The effects of the methods were identified by comparing the manikin based equivalent temperatures. The optimal thermal comfort level for both patient and medical staff would obtained when two conventional cotton blankets were used with extra clothing for the patient, at room air temperature adjusted to be comfortable for the doctor.
机译:目的是确定安装在天花板上的辐射采暖板是否可以为患者房间的乘员提供热舒适感,并确定同时为患者和医护人员提供最佳热环境的方法。实验是在一个类似于单人病房的气候室中进行的,该气候室单独使用对流空调,也可以与安装在天花板上的辐射加热板组合使用。两个人体模型模拟了一名躺在床上的病人和一名站在病人旁边的医生。常规的棉毯,电热毯,电床垫用于为患者提供局部加热。通过比较基于人体模型的等效温度来确定方法的效果。当将两个常规的棉毯与额外的衣物搭配使用时,在为患者感到舒适的室温下,可以为患者和医务人员提供最佳的热舒适度。