首页> 外文会议>11th International Conference on Electrical Machines and Systems(第11届国际电机与系统会议)论文集 >The Optimal Design and 3D Thermal Analysis of Stator for Evaporative Cooling Hydrogenerator of Three Gorges Right Bank Underground Hydropower Station
【24h】

The Optimal Design and 3D Thermal Analysis of Stator for Evaporative Cooling Hydrogenerator of Three Gorges Right Bank Underground Hydropower Station

机译:三峡右岸地下水电站蒸发冷却水轮发电机定子的优化设计与3D热分析。

获取原文

摘要

In order to make Three Gorges' evaporative cooling hydrogenerators have the best thermal performance, optimal design for the evaporative cooling system of stator bar has been made, and the thermal characteristic of the stator was analyzed by 3D FEM coupled analysis tool in this paper. The results provide the design basis for the industrial unit and show the evaporative cooling generator has lower stator temperature level and even temperature distribution.
机译:为了使三峡蒸发冷却水轮发电机具有最佳的热性能,本文对定子棒的蒸发冷却系统进行了优化设计,并通过3D FEM耦合分析工具对定子的热特性进行了分析。结果为工业机组的设计提供了依据,表明蒸发冷却发电机定子温度水平较低,温度分布均匀。