There is an increasing call for fast and reliable methods for continuous monitoring of microbial drinking water quality in order to protect public health. The potential for Adenosine triphosphate (ATP) measurements as a real-time analysis for continuous monitoring of microbial drinking water quality was investigated through simulation of two contamination scenarios, i.e. drinking water contaminated with waste water and surface water at various concentrations. With ATP measurements it was possible to detect waste water diluted 1000-10,000 times in drinking water depending on sensitivity of reagent kit. Surface water diluted 100-1000 times was detected in drinking water with ATP measurements. ATP has the potential as an early warning tool, especially in the period when the contamination concentration is high.
机译:为了保护公众健康,越来越需要快速可靠的方法来连续监测微生物饮用水的质量。通过模拟两种污染情景(即饮用水被各种浓度的废水和地表水污染),研究了三磷酸腺苷(ATP)测量作为实时分析以连续监测微生物饮用水质量的潜力。借助ATP测量,可以根据试剂盒的灵敏度检测饮用水中稀释1000-10,000倍的废水。用ATP测量在饮用水中检测到稀释100-1000倍的地表水。 ATP有潜力作为预警工具,尤其是在污染物浓度高的时期。