It is very common in technical design of transmission lines errors in the selection of materials to be used for grounding systems and do not take into account the type of soil and the material bases of the towers. This error can cause accelerated corrosion problems as which to go meet degrading and resistance values defined grounding for the design of the line, will cause increased likelihood of Back Flashover phenomena causing increased forced outputs actual lightning, to the point that exceeds the design, degrading the quality of service. This research presents a case study of electric transmission line towers have concrete bases type "pillar" cylindrical where a poor selection of the material for the equity this accelerated corrosion filed within twenty (21) months after construction. Based on this research, experience and literature proposes a number of technical criteria which should be taken into account when choosing the materials for the grounding system of power transmission line in order to minimize corrosion problems and theft.
机译:在传输线的技术设计中,接地系统材料的选择常常会出现错误,并且没有考虑土壤类型和铁塔的材料基础,这是很常见的。此错误可能会导致加速腐蚀问题,从而导致退化,并且线路设计中定义的接地电阻值会导致出现反向闪络现象的可能性增加,从而导致强制输出实际雷电增加,甚至超过设计点,从而使线路性能下降。服务质量。这项研究提出了一个以输电线路铁塔为基础的“柱状”圆柱形混凝土基座的案例研究,这种材料在建设后二十(21)个月内就加速了腐蚀,因此缺乏公平的材料选择。基于这项研究,经验和文献提出了许多技术标准,在选择输电线路接地系统的材料时应考虑这些技术标准,以最大程度地减少腐蚀问题和盗窃。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号