首页> 外文会议>75th ARFTG Microwave Measurements Conference >Inter-laboratory comparison of reflection and transmission measurements in WR-06 waveguide (110 GHz to 170 GHz)
【24h】

Inter-laboratory comparison of reflection and transmission measurements in WR-06 waveguide (110 GHz to 170 GHz)

机译:WR-06波导(110 GHz至170 GHz)中反射和透射测量的实验室间比较

获取原文
获取原文并翻译 | 示例

摘要

This paper describes an exercise that was undertaken recently to compare reflection and transmission measurements in rectangular metallic waveguide from 110 GHz to 170 GHz (i.e. in the WR-06 waveguide size). The comparison involved making measurements on four devices fitted with ‘precision’ MIL-DTL-3922-67D style flanges. These devices were circulated amongst the nine organizations that chose to participate in the exercise. The comparison took place between August 2008 and September 2009. Results from the exercise are presented in graphical form along with a statistical summary showing average variability for the measurements. The authors believe this is the first time that such a comparison of measurements has been made at these frequencies. These results therefore provide a benchmark for the current state-of-the-art for measurements made in waveguide at these frequencies.
机译:本文介绍了最近进行的一项练习,以比较110 GHz至170 GHz(即WR-06波导尺寸)在矩形金属波导中的反射和透射测量。比较涉及在装有“精密” MIL-DTL-3922-67D型法兰的四台设备上进行测量。这些设备在选择参加该练习的9个组织中分发。比较是在2008年8月和2009年9月之间进行的。练习的结果以图形形式显示,并提供了统计摘要,这些摘要显示了测量的平均变异性。作者认为,这是首次在这些频率下进行测量比较。因此,这些结果为当前在这些频率下在波导中进行测量的最新技术提供了基准。