【24h】

Ocular Hazards of Q-switched Near-Infrared Lasers

机译:调Q近红外激光的眼部危险

获取原文
获取原文并翻译 | 示例

摘要

The threshold for laser-induced retinal damage in the rhesus eye was determined for wavelengths between 800 nm and 1200 nm. The laser source was a tunable Optical Parametric Oscillator (OPO) pumped by the 3rd harmonic of a Nd:YAG laser. The laser pulse duration was 3.5 ns. The wavelength dependence of the injury threshold is consistent with the prediction of a model based on the transmission of the preretinal ocular media, absorption in the retinal pigment epithelium, and variation of irradiance diameter resulting from chromatic aberration of the eye optics for wavelengths shorter than 1150 nm but was less consistent for longer wavelengths. The threshold for 24-hour observation was slightly lower than the threshold for 1-hour observation. These data form a basis for reexamination of the currently defined MPEs for wavelengths longer than 1200 nm.
机译:对于800nm至1200nm之间的波长,确定了恒河猴眼中激光引起的视网膜损伤的阈值。激光源是由Nd:YAG激光器的三次谐波泵浦的可调光参量振荡器(OPO)。激光脉冲持续时间为3.5 ns。损伤阈值的波长依赖性与基于视网膜前眼介质的透射,视网膜色素上皮的吸收以及波长小于1150的眼睛光学部件色差导致的辐照直径变化的模型预测相一致纳米,但对于更长的波长则不一致。 24小时观察的阈值略低于1小时观察的阈值。这些数据构成了对超过1200 nm波长的当前定义的MPE进行重新检查的基础。