首页> 外文会议>International Cryogenic Engineering Conference(ICEC 20) >Comparison of the performance of regenerators to counterflow heat exchangers
【24h】

Comparison of the performance of regenerators to counterflow heat exchangers

机译:蓄热室与逆流热交换器的性能比较

获取原文

摘要

Irreversible processes in regenerators and heat exchangers limit the performance of cryocoolers. In our research we study the possibility to avoid regenerators in pulse-tube refrigerators (PTR's) by using two identical PTR's operating in opposite phase. The two regenerators are replaced by one counterflow heat exchanger. In this contribution we treat the performances of regenerators and heat exchangers from a fundamental point of view. The losses in the two systems are calculated from the entropy production due to the various irreversible processes. The expressions are brought in special forms which make comparison relatively easy.
机译:再生器和热交换器中不可逆的过程限制了低温冷却器的性能。在我们的研究中,我们研究了通过使用两个反相运行的相同PTR,避免在脉冲管制冷机(PTR)中使用再生器的可能性。两台蓄热器由一个逆流热交换器代替。在这一贡献中,我们从基本的角度看待了再生器和热交换器的性能。由于各种不可逆过程,根据熵产生来计算两个系统中的损失。表达式采用特殊形式,使比较相对容易。