DAMAGE ASSESSMENTS AND DESIGN CONSIDERATIONS OF HIGH-TEMPERATURE HEADERS

机译:高温割台的损伤评估和设计考虑

获取原文
获取原文并翻译 | 示例

摘要

The original superheater outlet headers on TVA's Cumberland Units 1 and 2 have been high maintenance items throughout the life of the units. Periodic assessment and maintenance have been required to minimize the units' forced outrage rate. The problem areas include the ligament and bore hole cracking, tube stub pull out, and circumferential weld defects. Failure mechanisms were identified and root cause analyses were performed. Replacement of the headers were justified based on lost generation from forced outages. The BLESS computer code was used to evaluate the new design. German Code TRD-301 was also used to investigate the impact of fast load ramping. Potential new header materials were considered Tube spacing and connecting piping were rearranged. Several fabrication details were revised to eliminate previous problems. Barkhausen Noise and X-ray defraction techniques were used to quantify the residual strain in the weldment and heat-affected zone from the fabrication process.
机译:TVA的Cumberland 1号和2号机组的原始过热器出口集管在其整个使用寿命期间都是高维护项目。需要定期评估和维护以最大程度地降低设备的强制使用率。问题区域包括韧带和钻孔开裂,管接头拔出以及周向焊接缺陷。确定故障机制并进行根本原因分析。根据强制中断造成的发电量损失,更换接头是合理的。 BLESS计算机代码用于评估新设计。德国规范TRD-301也用于研究快速负载加速的影响。考虑了可能的新集管材料。重新布置了管间距和连接管道。修改了一些制造细节以消除以前的问题。使用Barkhausen噪声和X射线衍射技术来量化制造过程中焊件和热影响区的残余应变。