The key measurement instruments in the control of the base metal flotation are the on-line elemental analyzers like the Courier X-ray fluorescence analyzer. The calibration of the analyser is one of the key factors in the operation of the X-ray fluorescence analyser. The quality of the analyses is limited by the quality of the calibration of the assay calculation model. The co-linearity of the measurement information is problematic for the multi-linear regression used in the assay calculation and calibration. In this study two new regression methods are introduced for the assay calculation and calibration: Principal Component Regression and Partial Least Squares regression. These methods utilize the idea of internal structure of data - latent structure that handles the co-linearity internally.
机译:控制贱金属浮选的关键测量仪器是在线元素分析仪,例如Courier X射线荧光分析仪。分析仪的校准是X射线荧光分析仪运行的关键因素之一。分析的质量受到测定计算模型的校准质量的限制。测量信息的共线性对于化验计算和校准中使用的多线性回归是有问题的。在这项研究中,为测定的计算和校准引入了两种新的回归方法:主成分回归和偏最小二乘回归。这些方法利用了数据内部结构的思想-在内部处理共线性的潜在结构。