GUILLOTINE BREAKS OF FW LINES AT LOVIISA 440

机译:LOVIISA 440的几条生产线的豆胶断裂

获取原文
获取原文并翻译 | 示例

摘要

The Loviisa Nuclear Power Plant owned by Fortum (by IVO until 1998) consists of two VVER 440 units dating back to the late 70s and the early '80s. A control programme was developed in 1982-1983 to manage erosion corrosion in the secondary system piping and components. The scope of the control programme was enlarged after the Surry accident in 1986 but still the control programme was based on the operation experience and two-phase flow conditions. Due to shortcomings of the control programme, the guillotine pipe break of the feed water system piping occurred in 1990 at Unit 1. Erosion corrosion adjacent to the flow control orifice in the feed water discharge line was incorrectly assumed to be lower than in other during the previous outages inspected fittings (tees, 90 degree elbows, throttles, etc.). However, in spite of the large efforts put on the improving the inspection programme the second guillotine pipe break of the feed water system occurred in 1993 at Unit 2. In order to diminish erosion corrosion of the feed water system piping secondary water chemistry was changed from neutral to alkaline water chemistry in 1994 at Unit 2 and in 1995 at Unit 1, respectively. Also change of larger extent of carbon steel piping to low alloy or stainless steel piping has been carried out.
机译:Fortum拥有的Loviisa核电站(由IVO收购,直到1998年)由两个VVER 440机组组成,其历史可追溯到70年代末和80年代初。 1982-1983年制定了一个控制程序,以管理二次系统管道和组件中的腐蚀腐蚀。 1986年萨里(Surry)事故发生后,控制程序的范围有所扩大,但该控制程序仍基于操作经验和两相流动条件。由于控制程序的缺陷,给水系统管道的断头台管道断裂发生在1990年的1号机组。错误地认为,给水排放管道中流量控制孔附近的腐蚀腐蚀低于其他情况。先前的停机检查过的配件(三通,90度弯头,节流阀等)。然而,尽管付出了巨大的努力来改进检查程序,但给水系统的第二个断头台管道破裂还是在1993年发生在2号机组上。为了减少给水系统管道的腐蚀腐蚀,将二次化学改为分别于1994年在第2单元和1995年在第1单元进行中性到碱性水化学反应。另外,已经进行了将更大范围的碳钢管道改变为低合金或不锈钢管道的改变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号