首页> 外文会议>IEEE Industry Applications Society Annual Meeting >Fault Detection and Protection of Three-level Neutral-Point-Clamped PWM Voltage Source Converters
【24h】

Fault Detection and Protection of Three-level Neutral-Point-Clamped PWM Voltage Source Converters

机译:三级中性点钳位PWM电压源转换器的故障检测与保护

获取原文

摘要

This paper presents the detection and protection methods uniquely associated with three-level NPC voltage source converters. The line-to-ground fault can cause significant dc-link neutral voltage and therefore can be effectively detected and located through monitoring the voltage without extra hardware. The inner device short in the three-level phase-leg can lead to dc-link voltage unbalance and doubling the stress on capacitors and devices, which must be suppressed for the safe operation of the converter. Two overvoltage limiting methods are proposed to limit the overvoltage. The design of both the ground fault detection and overvoltage limiting has been covered in the paper. The schemes are verified through simulation and experiments.
机译:本文介绍了与三级NPC电压源转换器独特相关的检测和保护方法。线到接地故障可能会导致显着的直流链路中性电压,因此可以通过监控无需额外硬件的电压来有效地检测和定位。三级相位腿中的内部器件可以导致直流链路电压不平衡,并将压力加倍,电容器和器件上的应力加长,这必须抑制转换器的安全操作。提出了两个过压限制方法以限制过电压。纸张覆盖了地面故障检测和过电压限制的设计。通过模拟和实验验证这些方案。