Experiments were conducted to compare two laboratory techniques for measuring thermal conductivity of unsaturated soils: (1) a modified transient plane source (MTPS) method for nondestructive measurements using a planar, interfacial heat reflectance sensor; and (2) a transient line source (TLS) method utilizing a single-probe heat source. Thermal conductivity and thermal conductivity dry out curves (TCDCs) were measured for two sands, including a poorly graded sand, and a well-graded sand with silt. The MTPS sensor resulted in larger thermal conductivity values than the TLS sensor for pore water saturations greater than 50%. At low pore water saturation, the MTPS sensor potentially underestimates thermal conductivity due to poor sensor-soil contact potentially resulting from the absence of water bridges between the sensor and soil surface.
机译:进行了实验以比较用于测量不饱和土的导热率的两种实验室技术:(1)使用平面,界面热反射传感器的非破坏性测量改进的瞬态平面源(MTPS)方法; (2)利用单探针热源的瞬态线源(TLS)方法。热导率和导热率干燥曲线(TCDC)为两个砂体测量,包括较差的沙子,以及淤泥的良好分级砂。 MTPS传感器导致比TLS传感器大于50%的TLS传感器。在低孔隙水饱和度下,由于在传感器和土壤表面之间没有水桥的缺陷导致的传感器 - 土壤接触差,MTPS传感器可能低估导热率。