A few key challenges to utilizing a merged sanitary/storm sewer system were identified. One ofthe more significant challenges was the separate routines used to determine the inflow to therespective systems. The empirical, unit hydrograph methodology used in the sanitary sewermodel does not interact with the deterministic, overland flow routing calculations used in thestormwater collection system model. If a new model were to be constructed where onemethodology could be applied to both systems (e.g. the unit hydrograph methodology applied tothe storm sewer model, or the runoff routing applied to the sanitary sewer model), the mergedmodel would be much more effective and useful.
机译:确定了利用合并的卫生/雨水排放系统的几个关键挑战。之一 更大的挑战是用于确定流入量的单独程序 各自的系统。下水道中使用的经验单位水线法 该模型不与确定性,陆上流动路线计算中使用的交互作用 雨水收集系统模型。如果要建立一个新的模型, 该方法可以同时应用于这两个系统(例如,将单位水位图方法应用于 雨水管道模型或应用于污水管道模型的径流路径),合并后的 模式将更加有效和有用。