首页> 外文会议>National conference on noise control engineering >An Analysis of the Integrity of the ISO 10302-1 Small Air-Moving Device Test Plenum under High Static-Pressure Loading
【24h】

An Analysis of the Integrity of the ISO 10302-1 Small Air-Moving Device Test Plenum under High Static-Pressure Loading

机译:高静压载荷下ISO 10302-1小型空气移动装置测试全体会议的完整性分析

获取原文

摘要

Small air-moving devices have continued to evolve, in particular with the introduction of counter-rotating fans, to reach airflow and static pressure performance capabilities far exceeding their predecessors. This is problematic when attempting to test these devices according to the small-air moving device test standard ISO 10302-1 because the test plenum was experimentally found to be limited to a static pressure of 750 Pa, which is substantially less than the maximum static pressure at which some modern fans can operate. This paper will revisit the analysis of the static-pressure capacity of the test plenum through experimental and computational methods, including the influence of the size and material properties of the polyester film, in furtherance of establishing a plenum capable of testing high-pressure fans across their full range of operation.
机译:小型空气运动装置一直在不断发展,特别是随着反向旋转风扇的出现,其气流和静压性能已经远远超过了其前身。在尝试根据小型空气移动设备测试标准ISO 10302-1测试这些设备时,这是有问题的,因为通过实验发现测试气室仅限于750 Pa的静压,该静压明显小于最大静压一些现代的粉丝可以在此运行。本文将通过实验和计算方法(包括聚酯薄膜的尺寸和材料性能的影响),重新探讨对测试增压室的静压能力的分析,以进一步建立能够测试整个高压风机的增压室。他们的全方位运作。