The aim of this work is to study the influence of contamination with infusion in clinical chemistry tests and to design an algorithm for detection of inadequate blood specimen. We show that panic value of postassium (K+)/ glucose (GLU) or decrease of total protein (TP), albumin (ALB), urea nitrogen (BUN), uric acid (UA), high-density lipoprotein cholesterol (HDL-C), total cholesterol (T-CHO), and calcium (Ca) is an index of contamination of drip infusion solution. Through a clinical study, we show that our algorithm is useful for preventing adverse medical errors.
机译:这项工作的目的是研究污染在临床化学测试中的污染的影响,并设计一种检测血液标本不足的算法。 我们展示了促乳腺(k +)/葡萄糖(glu)的恐慌价值或总蛋白质(tp),白蛋白(alb),尿素氮(bun),尿酸(Ua),高密度脂蛋白胆固醇(HDL-C)的降低 ),总胆固醇(T-CHO)和钙(CA)是滴灌溶液的污染指数。 通过临床研究,我们表明我们的算法对于防止不良医疗错误是有用的。