首页> 外文会议>European Congress of Neurosurgery >Stereotactic Needle Guided Procedures: Frame-based Versus Frameless Systems
【24h】

Stereotactic Needle Guided Procedures: Frame-based Versus Frameless Systems

机译:立体定向针指导手术:基于帧的与无框架系统

获取原文

摘要

Frame-based stereotactic systems have provided the gold-standard method of needle guidance for tumor biopsy, aspiration of fluid masses and catheter placement. To overcome some of the disadvantages of conventional stereotaxy, frameless stereotactic systems are being used with increasing frequency for performing stereotactic needle guided procedures. In this paper Authors report a personal series of 115 needle guided procedures, 65 performed with conventional stereotactic frame and 50 accomplished with frameless image-guided system (IGS), in order to compare the clinical accuracy and evaluate advantages and limits of both technologies. This comparison study demonstrates that frameless stereotaxy brings with it tangible advantages while maintaining the same accuracy of standard frame-based method.
机译:基于帧的立体定向系统已经为肿瘤活组织检查,流体质量和导管放置的吸入提供了针指导的金标准方法。为了克服常规立体岩的一些缺点,无框架的立体定向系统正在随着用于执行立体定向针引导程序的增加而使用频率。本文提交了一系列115针指导程序,65次,用传统的立体定向框架进行,50以无框架图像引导系统(IGS)完成,以比较临床准确性和评估两种技术的优缺点。这种比较研究表明,无框架的立体框架带来了它的实际优势,同时保持了基于标准帧的方法的相同精度。