首页> 外文会议>The International Conference Exhibition on Liquefied Natural Gas >BASIC DESIGN OF PYEONGTAEK LNG RECEIVING TERMINAL-II OF KOREA GAS CORPORATION LA CONCEPTION DE BASE DU TERMINAL METHANIER PYEONGTAEK-II
【24h】

BASIC DESIGN OF PYEONGTAEK LNG RECEIVING TERMINAL-II OF KOREA GAS CORPORATION LA CONCEPTION DE BASE DU TERMINAL METHANIER PYEONGTAEK-II

机译:Pyeongtaek LNG的基本设计接收韩国燃气公司的终端-II La Conception de Base Du Tender Methanier Pyeongtaek-II

获取原文

摘要

The existing Pyeongtaek LNG receiving terminal I of Korea Gas Corporation (KOGAS) is the first LNG terminal in Korea which was constructed on a partially reclaimed land and started the commercial operation in 1986. This terminal has a storage capacity of 1,000,000 m~3 in 10x100,000 m~3 membrane containment LNG storage tanks and a gasification capacity of 2,020 ton/hour. KOGAS decided to construct the Pyeongteak LNG terminal II on a new reclaimed area located at the north of the existing LNG terminal I. This terminal will be designed for 10 LNG storage tanks and a vaporization capacity of 720 ton/hour. The first phase construction will be done from 2003 to 2008 for 4 LNG storage tanks of 140,000 m~3 and gasification process of 720 ton/hour. The jetty No.1 constructed in 1986 for the LNG terminal I will be newly assigned to the terminal II for unloading LNG. The send-out process can be extended to a capacity of 1,440 ton/hour. This paper outlines the basic design and features of the Pyeongtaek LNG terminal II conducted by KOGAS. Some important considerations are taken for a smooth linkage with the existing terminal I and efficient dealing with boil-off gas produced in the terminal I and II.
机译:现有的Pyeongtaek LNG接收终端I韩国燃气公司(Kogas)是韩国的第一届LNG终端,在部分回收的土地上建造,并于1986年开始商业运营。该终端在10x100中的存储容量为1,000,000 m〜3 ,000米〜3膜壳体液体储罐和气化容量为2,020吨/小时。 Kogas决定在位于现有LNG终端I的北部的新的再生区域构建PYEONGTEAK LNG终端II。该终端将设计为10液化天然气储罐和720吨/小时的汽化容量。第一阶段建设将于2003年至2008年完成,4液化储罐140,000毫米,气化过程为720吨/小时。 1986年构造的码头1对于LNG终端I的码头1将被新分配给终端II以卸载LNG。发送过程可以扩展到1,440吨/小时的容量。本文概述了Kogas进行的PYEONGTAEK LNG终端II的基本设计和特征。使用现有的终端I和有效地处理在端子I和II中产生的蒸发气体,采取一些重要的考虑。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号