首页> 外文会议>International Conference on Remediation of Chlorinated adn Recalcitrant Compounds >Optimization of a Water Supply Well for Recovery of a Trichloroethene Plume
【24h】

Optimization of a Water Supply Well for Recovery of a Trichloroethene Plume

机译:优化水供应良好,以回收三氯乙烯羽流

获取原文

摘要

Incorporating existing water supply wells into a groundwater recovery and treatment system can be challenging. Water supply wells typically have long open intervals and produce water from multiple stratigraphic or fracture zones. Recovery wells used for groundwater remediation are generally designed to recover contaminant mass from specific zones while maximizing well drawdown to contain the spread of the contaminant plume. While there are perceived potential cost savings associated with using an existing water supply well versus. constructing a new recovery well, evaluation and possible modification of an existing water supply well can result in enhanced performance and potential cost savings. This paper describes the testing, implementation, operational results and cost savings associated with optimizing a 505 ft (154 m) deep water supply well (WELL-4) for recovery of a groundwater contaminant plume in a fractured bedrock aquifer.
机译:将现有的供水井纳入地下水回收和治疗系统可能具有挑战性。供水井通常具有长开放间隔,并从多个地层或骨折区域产生水。用于地下水修复的回收孔通常设计成从特定区域中回收污染物质量,同时最大化良好的绘图以含有污染羽流的扩散。虽然有与使用现有的供水良好与相比有关的潜在成本节约。构建新的恢复良好,对现有供水的评估和可能的修改可能导致增强的性能和潜在的成本节省。本文介绍了与优化505英尺(154米)深水供应良好(井-4)相关的测试,实施,操作结果和成本节约,以便在碎屑含水层中恢复地下水污染羽流。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有