Temperature Dependence of the Gorter-Mellink Exponent m Measured in a Channel Containing He II

机译:戈尔特-MELLINK指数M在包含HI II的通道中测量的戈尔特-MELLINK指数M的温度依赖性

获取原文

摘要

Steady state heat transport through He II was investigated. The exponent m in the Gorter-Mellink equation which gives heat flux dependence of the temperature gradient was measured in a wide range of heat flux. Our results indicate that there is no heat flux dependency of the exponent m in the heat flux region of our measurement. The exponent m is 3.4 at temperatures much lower than the lambda point and decreases down to 3.3 as the temperature approaches the lambda point.
机译:研究了通过他II的稳态热传输。在宽范围的热通量下测量给出温度梯度的热通量依赖性的Gorter-Mellink方程中的指数m。我们的结果表明,在我们测量的热通量区域中没有指数M的热通量依赖性。指数M在温度低于Lambda点的温度下为3.4,随着温度接近Lambda点,降低至3.3。