首页> 外文会议>American Society for Mass Spectrometry Conference on Mass Spectrometry and Allied Topics >Ion Chromatography and MS/MS Quantification of Polyphosphonates and Scale Inhibitors in High Ionic Strength Matrix Effluents
【24h】

Ion Chromatography and MS/MS Quantification of Polyphosphonates and Scale Inhibitors in High Ionic Strength Matrix Effluents

机译:离子色谱和MS / MS定量多相膦酸盐和高离子强度基质流出物中的水垢抑制剂

获取原文

摘要

The additio of scale and corrosion inhibitors to the water stream reduces corrosion and allows repeat water cycling. The minimum detection level established by this method shows that low-level quantitation of scale and corrosion inhibitors is possible, even in a high concentration of laboratory-simulated matrix. The recoveries of all of the compounds were within 15percent of the 100 ppb spike. The reproducibility of the matrix-spiked samples were all within 5percent, without internal standard correction. While there is no current EPA guideline for the amount of corrosion and scale inhibitors released into the environment, interest in the quantification of these products in released water has increased. Ion chromatography with the IonPac AS21 column afforded excellent separation, contributing to the development of a robust method for quantitation of scale and corrosion inhibitors in a high concentration anionic matrix.
机译:水流的规模和腐蚀抑制剂的添加剂减少了腐蚀并允许重复水循环。通过该方法建立的最小检测水平表明,即使在高浓度的实验室模拟基质中,也可以实现规模和腐蚀抑制剂的低级定量。所有化合物的回收率在100ppb穗的15平方内。基质掺入样品的再现性在5平方内,没有内部标准校正。虽然没有目前的EPA指南释放到环境中的腐蚀和抑制剂的量,但对释放水中这些产品的量化的兴趣增加了。离子色谱法与IONPAC AS21塔得到优异的分离,有助于在高浓度阴离子基质中定量规模和腐蚀抑制剂的稳健方法的发展。