首页> 外文会议>International Horticultural Congress >Microclimate Distribution in a Greenhouse Cooled by a Fog System
【24h】

Microclimate Distribution in a Greenhouse Cooled by a Fog System

机译:由雾系统冷却的温室微节化分布

获取原文

摘要

The aim of this study was to characterise the microclimate distribution in a greenhouse cooled by a mist system in comparison to the microclimate distribution of a roof ventilated greenhouse. For this purpose, air temperature, vapour pressure deficit and air velocity were measured in several positions inside an even-span greenhouse with a soilless rose crop, during periods with: (i) natural ventilation only, by means of a continuous roof vent and (ii) a mist-system operating associated with natural ventilation. The results indicated that fog induced a more homogeneous field for temperature and humidity, providing a more intensive mixing of the inside atmosphere, while natural ventilation induced high vertical temperature gradients.
机译:本研究的目的是在与雾系统的微气候分布相比,在由雾系统冷却的温室中的微节化分布表征。为此目的,在均线玫瑰作物内的几个位置测量空气温度,蒸汽压力缺损和空气速度,其中包括:(i)仅通过连续屋顶通风口和( ii)与自然通风相关的雾气系统。结果表明,雾诱导了更均匀的温度和湿度的田间,提供了更加强烈的内部气氛混合,而自然通风诱导高垂直温度梯度。