X-ray absorption/fluorescence spectroscopy probes valence states relative to a core level and thus provides an absolute energy reference. The core hole lifetime broadening can be reduced by restricting the fluorescence signal with a sub-eV crystal energy analyzer. We describe the design and first performance tests of adaptive optics for a bent-crystal analyzer which is characterized by a high counting efficency and a large solid angle acceptance. The device was designed for the determination of charge carrier dynamics in photoexcited semiconductors in laser pump, x-ray probe experiments. It can also be used in a wide range of near-edge spectroscopic applications and as an ultrafast laser/x-ray cross correlator...
机译:X射线吸收/荧光光谱探测效价态相对于核心水平,从而提供绝对能源参考。可以通过限制具有子EV晶体能量分析仪的荧光信号来降低芯孔寿命扩展。我们描述了弯曲晶体分析仪的自适应光学器件的设计和第一性能测试,其特征在于高计数效率和大的立体角度接受。该装置被设计用于在激光泵中的光透射半导体中测定电荷载体动力学,X射线探测实验。它还可以用于各种近边光谱应用,并作为超快激光/ X射线交叉相关器......