1. Must directly compare to a Diffusion Pump applied to this furnace and gun location to make a conclusion. 2. There may be other turbo pump designs that would decrease the bearing failure rates. 3. Turbo Pumping the Upper EB Gun Chamber Excellent pumping performance; Bearing failures resulted in questionable reliability in some gun locations. (over the melt zone); High Maintenance costs. Not user Serviceable; Eliminated the possibility of oil back-streaming into the upper gun chamber.
机译:1.必须直接与应用于该炉子的扩散泵和枪位置进行比较。 2.可能还有其他涡轮泵设计,可降低轴承故障率。 3.涡轮增压泵上EB枪室卓越的泵送性能;轴承故障导致某些枪位置可疑的可靠性。 (在熔体区);高维护成本。不是用户可维修;消除了油回流进入上枪室的可能性。