The distribution system is at the end of the power system and is directly connected to the energy consumers, which makes the distribution network a vital part of the power system. When a substation suffers an outage, electricity service restoration measures must be taken as soon as possible to reduce the loss. Traditional restoration methods have disadvantages such as poor stability and bad convergence. This paper proposed an approach to resume the power supply after a 35kV substation outage with the help of Dijkstra's shortest path algorithm. The proposed method is tested on a real distribution system. The result shows that the method is effective to solve the problem of electricity service restoration.
机译:分配系统位于电力系统的末端,直接连接到能量消费者,这使得分配网络成为电力系统的重要部分。当变电站遭受中断时,必须尽快采取电力服务恢复措施,以减少损失。传统恢复方法具有劣势和稳定性差和收敛性差的缺点。本文提出了一种借助Dijkstra的最短路径算法在35kV变电站停电后恢复电源的方法。所提出的方法在实际分配系统上进行了测试。结果表明,该方法有效地解决了电力服务恢复问题。