The Paclitaxel-eluting stents (PTX) with three-layered polymer coating were studied in this work. The PLGA (polylactic acid-co-glycolic acid) with 15 percent PEG (poly ethylene glycol) concentration in blend have been applied for preparing multiple layer drug carrier and fabricated on the surface of 316L stainless steel stents by ultrasonic atomization spraying method. The Paclitaxel was explored in doses: (~255μg) for single layer coated PTX (30 wt%), and (~275μg) for multiple layer coated PTX in accordance. Pre- and post-expansion surface morphologies of multiple layer stent were examined by scanning electron microscopy (SEM). The Paclitaxel release kinetics was studied by comparative method of release profiles of single layer PTX with 3-layered polymer coated PTX. The biocompatibility by hemolysis ratio and dynamic clotting time with platelet adhesion measurements also was investigated.
机译:在这项工作中研究了具有三层聚合物涂层的紫杉醇洗脱支架(PTX)。共混物中具有15%PEG(聚乙二醇)浓度的PLGA(聚酰氯二乙二醇)浓度用于制备多层药物载体并通过超声雾化喷涂方法在316L不锈钢支架的表面上制造。针对单层涂覆的PTX(30wt%)和(〜275μg)的单层涂覆PTX,紫杉醇探讨通过扫描电子显微镜(SEM)检查多层支架的前后表面形态。通过用3层聚合物涂覆的PTX进行单层PTX的释放曲线的比较方法研究了紫杉醇释放动力学。研究了通过溶血率的生物相容性和具有血小板粘附测量的动态凝结时间。